• Pd Flowmeter for Horizontal Installation with Ce Approval
  • Pd Flowmeter for Horizontal Installation with Ce Approval
  • Pd Flowmeter for Horizontal Installation with Ce Approval
  • Pd Flowmeter for Horizontal Installation with Ce Approval
  • Pd Flowmeter for Horizontal Installation with Ce Approval
  • Pd Flowmeter for Horizontal Installation with Ce Approval

Pd Flowmeter for Horizontal Installation with Ce Approval

Accuracy: ≤±0.1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas, High Viscosity Liquid
Size: DN8mm -DN400mm
Sensor: Tube/Flange
Application: Energy Metering
Type: Volume Type Flow Meter
Samples:
US$ 825/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Shanghai, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (28)

Basic Info.

Model NO.
LSZ
Measuring Media
Liquid
Measuring Principle
Volumetric
Measurement Object
Closed Pipeline
Certification
JIS, DIN, GB, CE, ISO
Transport Package
Wooden Case
Specification
Size from 3/8inch to 16 inch
Trademark
YINUO
Origin
Shanghai, China.
HS Code
9026100000
Production Capacity
5000units Per Year

Product Description

LSZ- Double-Rotator Flowmeter
General
LSZ- Double-Rotator Flowmeter is the latest & international super-class volumetric-type flowmeter. It is a
type of precise instrument measuring and controlling liquid flow in the pipeline, featuring high measurement
precision, smooth running, free of pulsation, low noise, long service life and excellent adaptability to
viscosity etc.. Therefore, the product has been widely used in various fields such as petroleum, chemical,
metallurgy, electric power, shipping, traffic, dock, mine, thermal power, and foodstuff industries etc.. It is
especially suitable for commercial trade measurement for crude oil, high condensation oil, crude oil with
high water content, petroleum products, foodstuff and chemical solutions as well as measuring
management and control of engineering automation. The codes and characters displayed on the flowmeter
can be directly read locally. The photo-electric pulse converter equipped can output electric pulse(current)
signals to the displaying instrument and computer for handling. Thus, the flow in the pipeline can be
remotely controlled.
                                                           Pd Flowmeter for Horizontal Installation with Ce Approval
Principle
The measuring chamber of the double-rotator flowmeter consists of interior casing, a pair of helix rotators
and top & bottom cover plates. These formed a cavity with known volume which can be used as the
measuring unit for the flowmeter. The rotator of the flowmeter rotates under the tiny pressure difference
between the inlet and outlet and continually sends the liquid at inlet to the outlet after cavity
measurement(See Fig.2). The rotator transmits the rotating numbers to the counter by means of sealed
coupling and driving system so that the total volume of the liquid passing the flowmeter can be directly
displayed.

Picture 2: The Principle of LSZ- Flowmeter

                                                Pd Flowmeter for Horizontal Installation with Ce Approval

                                                          Pd Flowmeter for Horizontal Installation with Ce Approval
  1. Inner measuring chamber
  2. Chamber cases
  3. Rotors
LSZ-Bi-rotator Flowmeter is a positive displacement meter utilized in the most demanding applications requiring accuracy, long life and ruggedness. It features two precisely machined rotating members known as helical rotors which rotate and mesh within the meter's interior housing in order to form a measuring chamber of known volume which may be used to accurately determine volumetric flow rate as a function of the rotors' velocity. As liquid enters the intake of the measurement element, two finely timed rotors divide the liquid into precise segments of known volume and return those segments to the flowing stream. During this transition, the rotation of the two rotors is directly proportional to volumetric throughput. Volume indication is determined by mechanical output gearing leading to electronic or mechanical  registration devices

Main Technical Parameters                                 Table:1
Nominal Dia. (mm) 8~400
Accuracy ±0.1%, ±0.2% and ±0.5%
Pressure loss 0~1000mPa.s<80Kpa  1000~20000mPa.2<150KPa
Nominal pressure 1.6, 2.5, 4.0, 6.4 MPa
Temperature range -20°C ~ +80°C  +80°C ~ +150°C  +150°C ~ +250°C
Media viscosity 0~20000mPa.s
Ambient temperature -40°C ~ +70°C
Connected flange Can be custom-made
Photoelectric pulse(current)converter Exd II CT6(Excluding acetylene)
Electronic meterhead Exd II CT2-T6
Range of Flow       
For Accuracy: 0.5% and 0.2%                                                            Table.2
 
Nominal
Dia.
(mm)
Flow range m3/h Pulse equivalent liter/pulse
0.32-0.8mPa.s 0.8-2mPa.s 2-5mPa.s 5-400mPa.s 400-2000mPa.s 2000-20000mPa.s
Gasoline/ liquefied gas Kerosene Light diesel Crude oil, heavy oil Hi-viscosity
Liquid
Liquid with high water content & super-high viscosity liquid
0.5% 0.2% 0.5% 0.2% 0.5% 0.2% 0.5% 0.2% 0.5% 0.2% 0.5% 0.2%
15 0.6-3   0.4-4   0.4-4   0.4-4   0.3-2.4   0.3-2.4   0.001
25 3-8   1.5-10   1-10   1-10   1-8   1-6    
0.01
 
40 8-20 8-20 2.7-22 5.5-22 2.5-25 4.4-22 2.5-25 4.4-22 2.1-18 4.2-18 1.5-12 3-12
50 9-36 15-36 4.5-36 9-36 4-40 7.2-36 4-40 7.2-36 2.8-24 6-24 2.2-18 4.5-18
80 20-80 32-80 10-80 20-80 9-90 16-80 9-90 16-80 6.5-56 14-56 5-40 10-40  
 
 
0.1
100 25-100 40-100 13-100 25-100 12-120 20-100 12-120 20-100 8.5-72 18-72 6.5-54 14-54
150 55-225 88-220 31-250 57-225 25-250 44-220 25-250 44-220 18-150 38-150 12-100 25-100
200 90-360 150-360 50-400 90-360 40-400 72-360 40-400 72-360 28-240 53-210 20-160 40-160
250 135-540 180-540 68-540 135-540 60-600 108-540 60-600 108-540 42-360 90-360 30-240 60-240
300 220-900 300-900 112-900 225-900 100-1000 180-900 100-1000 180-900 70-600 150-600 54-450 113-450
400 400-1600 550-1600 200-1600 400-1600 180-1800 320-1600 180-800 320-1600 130-1100 275-1100 90-750 180-750
Double-Rotator Flowmeter
Accuracy: 0.1%                                      Table.3
 
Nominal
Dia.
(mm)
Flow range m3/h Pulse equivalent liter/pulse
0.32-2 mPa.s
 
2-5 mPa.s 5-50mPa.s   500-400          mPa.s 400-2000 mPa.s 2000-20000 mPa.s
Gasoline/ liquefied gas Kerosene Light diesel Crude oil, heavy oil Hi-viscosity
Liquid
Liquid with high water content & super-high viscosity liquid
40 11-22 9-22 7.5-22 7.5-22 7.5-22 4-12 3.3-10 0.001
50 18-36 14.4-36 12-36 12-36 12-36 7.5-22 6-18 0.01
80 40-80 32-80 26.7-80 26.7-80 26.7-100 16-48 13-40
100 50-100 40-100 34-100 34-100 34-100 24-72 18-54
150 115-220 90-220 73-220 73-220 73-220 40-120 30-90 0.1
200 180-360 144-360 120-360 120-360 120-360 60-180 50-150
250 270-540 216-540 180-540 180-540 180-540 100-300 60-180
300 450-900 360-900 300-900 300-900 300-900 200-600 150-450
400 800-1600 640-1600 530-1600 530-1600 530-1600 400-1200 300-900
Double-Rotator Flowmeter-(Electron Meter head)
Accuracy: 0.5%, 0.2%                                                   Table. 4
 
Nominal
Dia.
(mm)
Flow range m3/h Pulse equivalent liter/pulse
0.32-0.8mPa.s 0.8-2mPa.s 2-5mPa.s 5-4mPa.s 400-2000mPa.s 2000-20000mPa.s
Gasoline/ liquefied gas Kerosene Light diesel Crude oil, heavy oil Hi-viscosity
Liquid
Liquid with high water content & super-high viscosity liquid
0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.01
8 0.06-0.3 0.10-0.3 0.05-0.3 0.07-0.3 0.03-0.3 0.06-0.3 0.03-0.3 0.06-0.3 0.03-0.27 0.06-0.27 0.03-0.24 0.06-0.24
15A 0.2-0.8 0.27-0.8 0.1-1 0.2-1 0.1-1.5 0.1-1 0.1-1.5 0.1-1 0.1-0.8 0.16-0.8 0.08-0.7 0.15-0.7
15B 0.25-1 0.33-1 0.25-1.5 0.25-1 0.25-3 0.3-3 0.3-3 0.4-3 0.1-1.5 0.2-1.5 0.1-1.2 0.2-1.2
25 1.5-6 2-6 1.2-6 1.5-6 0.6-10 1.2-10 0.6-10 1.2-10 0.6-6 1.2-6 0.6-5 1.2-5 0.1
Double-Rotator Flowmeter-St. steel (-20°C ~ +80°C)
Accuracy: 0.5% and 0.2%                              Table.5
Nominal
Dia.
(mm)
Range of flow m3/h Pulse equivalent liter/pulse
0.32-0.8 mPa.s 0.8-2 mPa.s 2-5 mPa.s 5-400 mPa.s 400-2000 mPa.s 2000-20000 mPa.s
Gasoline/ liquefied gas Kerosene Light diesel, diesel Crude oil, heavy oil Hi-viscosity
Liquid
Liquid with high water content & super-high viscosity liquid
0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2
15 0.75-3   0.75-3   0.6-3   0.6-3   0.6-3   0.5-2.5   0.001
25 2-8   2-8   1.6-8   1.6-8   1.2-6   1-5  
40 6-24 8-24 6-24 8-24 4.8-
24
6-24 4.8-
24
6-24 3.6-
18
4-16 2.4-
12
2.5-10 0.01
50 9-36 12-36 9-36 12-36 7.2-
36
9-36 7.2-
36
9-36 4.8-
24
5.5-
22
3.6-
18
4-16
80 20-80 27-80 20-80 27-80 16-80 20-80 16-80 20-80 12-56 12-48 8-40 9-36 0.1
100 25-
100
34-
100
25-
100
34-
100
20-
100
25-
100
20-
100
25-
100
15-75 15-60 11-54 11-45
150 55-
220
75-
220
55-
220
75-
220
45-
220
55-
220
45-
220
55-
220
30-
150
35-
135
20-
100
23-90
200 90-
360
120-
360
90-
360
120-
360
72-
360
90-
360
72-
360
90-
360
43-
210
50-
200
32-
160
38-150
250 135-
540
180-
540
135-
540
180-
540
108-
540
135-
540
108-
540
135-
540
72-
360
90-
360
48-
240
60-240
300 225-
900
300-
900
225-
900
300-
900
180-
900
225-
900
180-
900
225-
900
120-
600
150-
600
90-
450
113-450
Double-Rotator Flowmeter-St. steel high temp. type (+80°C ~ +150°C)
Accuracy: 0.5, 0.2                                 Table.6
Nominal
Dia.
(mm)
Range of flow m3/h Pulse equivalent liter/pulse
2-5 mPa.s 5-50 mPa.s 50-400 mPa.s 400-2000 mPa.s 2000-20000 mPa.s
Light diesel Crude oil, heavy oil Crude oil, heavy oil Hi-viscosity
Liquid
Liquid with high water content& super-high viscosity liquid
0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2
40 5.6-
22.5
7-20 5.6-
22.5
7-20 5.6-
22.5
7-20 4-15 4-12 3-12 3.5-10 0.01
50 9-36 10-32 9-36 10-32 9-36 10-32 4.5-22 7-20 4.5-18 6-18
80 20-80 25-75 20-80 25-75 20-80 25-75 12-48 13-40 9-36 10-30  
 
0.1
100 25-
100
30-90 25-
100
30-90 25-
100
30-90 15-60 17-50 11-45 14-40
150 45-
220
75-
220
45-
220
75-
220
45-
220
75-
220
35-
135
34-
100
23-90 27-80
200 90-
360
120-
360
90-
360
120-
360
90-
360
120-
360
50-
200
54-
160
38-150 43-130
250 135-
540
180-
540
135-
540
180-5
40
135-
540
180-
540
90-
360
120-
360
60-240 80-240
300 225-
900
300-
900
225-
900
300-
900
225-
900
300-
900
150-
600
200-
600
113-450 150-450
Double-Rotator Flowmeter-St. steel high temp. type (+150°C ~ +250°C)
Accuracy: 0.5% and 0.2%                        Table.7
 
Nominal
Dia.
(mm)
Range of flow m3/h Pulse equivalent liter/pulse
2-5 mPa.s 5-50 mPa.s 50-400 mPa.s 400-2000 mPa.s 2000-20000 mPa.s
Light diesel Crude oil, heavy oil Crude oil, heavy oil Hi-viscosity
Liquid
Liquid with high water content& super-high viscosity liquid
0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2
40 7.5-22.5 10-20 7.5-22.5 10-20 7.5-22.5 10-20 5-15 6-12 4-12 5-10 0.01
50 12-36 16-32 12-36 16-32 12-36 16-32 7.5-
22.5
10-20 6-18 9-18
80 26.7-80 35-75 26.7-80 35-75 26.7-80 35-75 16-48 20-40 12-36 15-30  
0.1
100 34-
100
45-90 34-
100
45-90 34-
100
45-90 20-60 25-50 15-45 20-40
150 75-
220
110-
220
75-
220
110-
220
75-
220
110-
220
45-135 50-100 30-90 40-80
200 120-
360
180-
360
120-
360
180-
360
120-
360
180-
360
65-
200
80-
160
50-
150
65-130
 

Double-Rotator Flowmeter-Carbon steel high temp. type (+150°C ~ +250°C)
     Accuracy: 0.5, 0.2                                  Table.8
Nominal
Dia.
(mm)
Range of flow m3/h Pulse equivalent liter/pulse
2-5 mPa.s 5-50 mPa.s 50-400 mPa.s 400-2000 mPa.s 2000-20000 mPa.s
Light diesel Crude oil, heavy oil Crude oil, heavy oil Hi-viscosity
Liquid
Liquid with high water content& super-high viscosity liquid
0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2
40 4.5-22.5 5.6-22.5 4.5-22.5 5.6-22.5 4.5-22.5 5.6-22.5 4.2-18 5-15 3-12 4-12 0.01
50 7.2-36 9-36 7.2-
36
9-36 7.2-
36
9-36 6-24 7.5-
22.5
4.5-
18
5.5-17.5
80 16-80 20-80 16-80 20-80 16-80 20-80 14-56 16-48 10-40 12-36 0.1
100 20-100 25-100 20-100 25-100 20-100 25-100 18-72 20-60 14-54 16-48
150 45-220 55-220 45-220 55-220 45-220 55-220 38-150 45-135 25-100 30-90
200 72-360 90-360 72-360 90-360 72-360 90-360 53-210 65-200 40-160 50-150
250 108-540 135-540 108-540 135-540 108-540 135-540 72-360 90-360 60-240 80-240
300 180-900 225-900 180-900 225-900 180-900 225-900 120-600 150-600 113-450 150-450
Note: The flowmeter is also suitable for interim measurement during installing/uninstalling and ship installing.

Applications:
Pd Flowmeter for Horizontal Installation with Ce Approval
Pd Flowmeter for Horizontal Installation with Ce Approval


They chose YINUO
Pd Flowmeter for Horizontal Installation with Ce Approval








 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
192
Year of Establishment
1999-06-24