Double Rotator Flow Meter for Ship Yard with BV CCS

Product Details
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas, High Viscosity Liquid
Size: DN8mm -DN400mm
Still deciding? Get samples of US$ 916/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (28)
  • Double Rotator Flow Meter for Ship Yard with BV CCS
  • Double Rotator Flow Meter for Ship Yard with BV CCS
  • Double Rotator Flow Meter for Ship Yard with BV CCS
  • Double Rotator Flow Meter for Ship Yard with BV CCS
  • Double Rotator Flow Meter for Ship Yard with BV CCS
  • Double Rotator Flow Meter for Ship Yard with BV CCS
Find Similar Products

Basic Info.

Model NO.
LSZ
Sensor
Tube/Flange
Application
Energy Metering
Type
Volume Type Flow Meter
Measuring Media
Liquid
Measuring Principle
Volumetric
Measurement Object
Closed Pipeline
Certification
JIS, DIN, GB, CE, ISO
Warranty Peroid
12 Months After The Installation
Power Supply
3.6V 24VDC
Signal Output
Pulse 4-20mA Hart
Working Temperature
-20 to 250 C Deg
Working Pressure
0~64 Bar
Approval
BV CCS Ce Atex Nepsi
Material
Cast Steel Ss304 Ss316
Transport Package
Wooden Case
Specification
Size from 3/8inch to 16 inch
Trademark
YINUO
Origin
Shanghai, China.
HS Code
9026100000
Production Capacity
5000units Per Year

Product Description

 
LSZ- Double rotator flowmeter 
Double Rotator Flow Meter for Ship Yard with BV CCS
General
LSZ-Jacket flowmeter find extensive use in flow measuring appliations where process materials tends to become highly visous, solidify, or extract as line temperature drops, or where process fluids must be controlled at a specific temperature. Measurement is made while steam or hot oil is allowed to circulate through the jacked enclosure.
 
  Features
  • Superior accuracy to 0.1% of reading over 30:1 turn-down
  • Self-lubricating Very low noise and vibration
  • Rugged double case construction prevents loss of calibration due to changes in pressure or temperature
  • No oscillating, reciprocating or sliding parts or cranks to wear or disturb the balanced rotary action  
  • Field proven in precise tempering of the process fluid that tends to solidify, requiring heat retention.
  • Flowmeter body is of pocketless design-an ideal construction for a jacketed flowmeter.
  • A complete line of meter sizes, registers pulse generators, receiving instruments, etc. are available to meet widely varies  
     
    Construction and Liquid to be metered( Fullly Jacketed)
     
 Sectional View
 
Description Liquids to be metered
 Double Rotator Flow Meter for Ship Yard with BV CCS
 
Pocketless construction( transmission system: Magnetic coupling)
Max. operating pressure( pressure of fluid to be metered):1.18MPa
Bitumen, DMT, phthalic
Anhydride,
Naphthalene, etc.
 
 
 
 
Construction and Liquid to be metered( Standard Jacketed)

 General Specification
  • Meter body
              Item             Description
Nominal size mm 08~400
Construction Double-case construction
Applicable fluid Water petroleum liquid foods chemical liquids
Flow range See flow range table
Operating temp.range
+
+80~+150°C
+150°C~+250°C
Accuracy 0.2% 0.5%
Repeatability 0.067% 0.167%
Materials Body Cast steel or 304 stainless steel or 316 stainless steel
Rotors Cast steel or 304 stainless steel or 316 stainless steel
Bearings Cast steel or 304 stainless steel or 316 stainless steel
 
 
Register Specifications Model M1
Item Description
Meter size Round Mechanical Register
Units Indicated Stere
Pointer Rotation Clockwise
Local display(LCD) Cumulative totalizing counter 0.1m3(std)  0.01m3  0.001m3
Resettable counter    No
Instantaneous flowrate 0.01m3/h(std)
Power supply Without output signal Installed lithium battery
With output signal External power source 24 VDC
Ambient temperature -40°C ~ +70°C
Explosionproof configuration Non-explosionproof type
Exd II CT2~T6
Degree of Protection for enclosure IP65
Note, output signal must matched with LPJ-I/F Photoelectric Pulse, then current signal or pulse signal could be chose
 
 
Model VR
Item Description
Meter size Square Mechanical Register
Units Indicated Stere
Local display(LCD) Cumulative totalizing counter 0.1m3(std)  0.01m3  0.001m3
Resettable counter 0.1m3(std)  0.01m3  0.001m3
Instantaneous flowrate  No
Power supply Without output signal Installed lithium battery
With output signal External power source 24 VDC
Ambient temperature -40°C ~ +70°C
Explosionproof configuration Non-explosionproof type
Exd II CT2~T6
Degree of Protection for enclosure IP65
  1. Note, output signal must matched with LPJ-I/F Photoelectric Pulse, then current signal or pulse signal could be chose


    Main Technical Parameters                                 Table:1
    Nominal Dia. (mm) 8~400
    Accuracy ±0.1%, ±0.2% and ±0.5%
    Pressure loss 0~1000mPa.s<80Kpa  1000~20000mPa.2<150KPa
    Nominal pressure 1.6, 2.5, 4.0, 6.4 MPa
    Temperature range -20°C ~ +80°C  +80°C ~ +150°C  +150°C ~ +250°C
    Media viscosity 0~20000mPa.s
    Ambient temperature -40°C ~ +70°C
    Connected flange Can be custom-made
    Photoelectric pulse(current)converter Exd II CT6(Excluding acetylene)
    Electronic meterhead Exd II CT2-T6
    Range of Flow       
    For Accuracy: 0.5% and 0.2%                                                            Table.2
     
    Nominal
    Dia.
    (mm)
    Flow range m3/h Pulse equivalent liter/pulse
    0.32-0.8mPa.s 0.8-2mPa.s 2-5mPa.s 5-400mPa.s 400-2000mPa.s 2000-20000mPa.s
    Gasoline/ liquefied gas Kerosene Light diesel Crude oil, heavy oil Hi-viscosity
    Liquid
    Liquid with high water content & super-high viscosity liquid
    0.5% 0.2% 0.5% 0.2% 0.5% 0.2% 0.5% 0.2% 0.5% 0.2% 0.5% 0.2%
    15 0.6-3   0.4-4   0.4-4   0.4-4   0.3-2.4   0.3-2.4   0.001
    25 3-8   1.5-10   1-10   1-10   1-8   1-6    
    0.01
     
    40 8-20 8-20 2.7-22 5.5-22 2.5-25 4.4-22 2.5-25 4.4-22 2.1-18 4.2-18 1.5-12 3-12
    50 9-36 15-36 4.5-36 9-36 4-40 7.2-36 4-40 7.2-36 2.8-24 6-24 2.2-18 4.5-18
    80 20-80 32-80 10-80 20-80 9-90 16-80 9-90 16-80 6.5-56 14-56 5-40 10-40  
     
     
    0.1
    100 25-100 40-100 13-100 25-100 12-120 20-100 12-120 20-100 8.5-72 18-72 6.5-54 14-54
    150 55-225 88-220 31-250 57-225 25-250 44-220 25-250 44-220 18-150 38-150 12-100 25-100
    200 90-360 150-360 50-400 90-360 40-400 72-360 40-400 72-360 28-240 53-210 20-160 40-160
    250 135-540 180-540 68-540 135-540 60-600 108-540 60-600 108-540 42-360 90-360 30-240 60-240
    300 220-900 300-900 112-900 225-900 100-1000 180-900 100-1000 180-900 70-600 150-600 54-450 113-450
    400 400-1600 550-1600 200-1600 400-1600 180-1800 320-1600 180-800 320-1600 130-1100 275-1100 90-750 180-750
    Double-Rotator Flowmeter
    Accuracy: 0.1%                                      Table.3
     
    Nominal
    Dia.
    (mm)
    Flow range m3/h Pulse equivalent liter/pulse
    0.32-2 mPa.s
     
    2-5 mPa.s 5-50mPa.s   500-400          mPa.s 400-2000 mPa.s 2000-20000 mPa.s
    Gasoline/ liquefied gas Kerosene Light diesel Crude oil, heavy oil Hi-viscosity
    Liquid
    Liquid with high water content & super-high viscosity liquid
    40 11-22 9-22 7.5-22 7.5-22 7.5-22 4-12 3.3-10 0.001
    50 18-36 14.4-36 12-36 12-36 12-36 7.5-22 6-18 0.01
    80 40-80 32-80 26.7-80 26.7-80 26.7-100 16-48 13-40
    100 50-100 40-100 34-100 34-100 34-100 24-72 18-54
    150 115-220 90-220 73-220 73-220 73-220 40-120 30-90 0.1
    200 180-360 144-360 120-360 120-360 120-360 60-180 50-150
    250 270-540 216-540 180-540 180-540 180-540 100-300 60-180
    300 450-900 360-900 300-900 300-900 300-900 200-600 150-450
    400 800-1600 640-1600 530-1600 530-1600 530-1600 400-1200 300-900
    Double-Rotator Flowmeter-(Electron Meter head)
    Accuracy: 0.5%, 0.2%                                                   Table. 4
     
    Nominal
    Dia.
    (mm)
    Flow range m3/h Pulse equivalent liter/pulse
    0.32-0.8mPa.s 0.8-2mPa.s 2-5mPa.s 5-4mPa.s 400-2000mPa.s 2000-20000mPa.s
    Gasoline/ liquefied gas Kerosene Light diesel Crude oil, heavy oil Hi-viscosity
    Liquid
    Liquid with high water content & super-high viscosity liquid
    0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.01
    8 0.06-0.3 0.10-0.3 0.05-0.3 0.07-0.3 0.03-0.3 0.06-0.3 0.03-0.3 0.06-0.3 0.03-0.27 0.06-0.27 0.03-0.24 0.06-0.24
    15A 0.2-0.8 0.27-0.8 0.1-1 0.2-1 0.1-1.5 0.1-1 0.1-1.5 0.1-1 0.1-0.8 0.16-0.8 0.08-0.7 0.15-0.7
    15B 0.25-1 0.33-1 0.25-1.5 0.25-1 0.25-3 0.3-3 0.3-3 0.4-3 0.1-1.5 0.2-1.5 0.1-1.2 0.2-1.2
    25 1.5-6 2-6 1.2-6 1.5-6 0.6-10 1.2-10 0.6-10 1.2-10 0.6-6 1.2-6 0.6-5 1.2-5 0.1
    Double-Rotator Flowmeter-St. steel (-20°C ~ +80°C)
    Accuracy: 0.5% and 0.2%                              Table.5
    Nominal
    Dia.
    (mm)
    Range of flow m3/h Pulse equivalent liter/pulse
    0.32-0.8 mPa.s 0.8-2 mPa.s 2-5 mPa.s 5-400 mPa.s 400-2000 mPa.s 2000-20000 mPa.s
    Gasoline/ liquefied gas Kerosene Light diesel, diesel Crude oil, heavy oil Hi-viscosity
    Liquid
    Liquid with high water content & super-high viscosity liquid
    0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2
    15 0.75-3   0.75-3   0.6-3   0.6-3   0.6-3   0.5-2.5   0.001
    25 2-8   2-8   1.6-8   1.6-8   1.2-6   1-5  
    40 6-24 8-24 6-24 8-24 4.8-
    24
    6-24 4.8-
    24
    6-24 3.6-
    18
    4-16 2.4-
    12
    2.5-10 0.01
    50 9-36 12-36 9-36 12-36 7.2-
    36
    9-36 7.2-
    36
    9-36 4.8-
    24
    5.5-
    22
    3.6-
    18
    4-16
    80 20-80 27-80 20-80 27-80 16-80 20-80 16-80 20-80 12-56 12-48 8-40 9-36 0.1
    100 25-
    100
    34-
    100
    25-
    100
    34-
    100
    20-
    100
    25-
    100
    20-
    100
    25-
    100
    15-75 15-60 11-54 11-45
    150 55-
    220
    75-
    220
    55-
    220
    75-
    220
    45-
    220
    55-
    220
    45-
    220
    55-
    220
    30-
    150
    35-
    135
    20-
    100
    23-90
    200 90-
    360
    120-
    360
    90-
    360
    120-
    360
    72-
    360
    90-
    360
    72-
    360
    90-
    360
    43-
    210
    50-
    200
    32-
    160
    38-150
    250 135-
    540
    180-
    540
    135-
    540
    180-
    540
    108-
    540
    135-
    540
    108-
    540
    135-
    540
    72-
    360
    90-
    360
    48-
    240
    60-240
    300 225-
    900
    300-
    900
    225-
    900
    300-
    900
    180-
    900
    225-
    900
    180-
    900
    225-
    900
    120-
    600
    150-
    600
    90-
    450
    113-450
    Double-Rotator Flowmeter-St. steel high temp. type (+80°C ~ +150°C)
    Accuracy: 0.5, 0.2                                 Table.6
    Nominal
    Dia.
    (mm)
    Range of flow m3/h Pulse equivalent liter/pulse
    2-5 mPa.s 5-50 mPa.s 50-400 mPa.s 400-2000 mPa.s 2000-20000 mPa.s
    Light diesel Crude oil, heavy oil Crude oil, heavy oil Hi-viscosity
    Liquid
    Liquid with high water content& super-high viscosity liquid
    0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2
    40 5.6-
    22.5
    7-20 5.6-
    22.5
    7-20 5.6-
    22.5
    7-20 4-15 4-12 3-12 3.5-10 0.01
    50 9-36 10-32 9-36 10-32 9-36 10-32 4.5-22 7-20 4.5-18 6-18
    80 20-80 25-75 20-80 25-75 20-80 25-75 12-48 13-40 9-36 10-30  
     
    0.1
    100 25-
    100
    30-90 25-
    100
    30-90 25-
    100
    30-90 15-60 17-50 11-45 14-40
    150 45-
    220
    75-
    220
    45-
    220
    75-
    220
    45-
    220
    75-
    220
    35-
    135
    34-
    100
    23-90 27-80
    200 90-
    360
    120-
    360
    90-
    360
    120-
    360
    90-
    360
    120-
    360
    50-
    200
    54-
    160
    38-150 43-130
    250 135-
    540
    180-
    540
    135-
    540
    180-5
    40
    135-
    540
    180-
    540
    90-
    360
    120-
    360
    60-240 80-240
    300 225-
    900
    300-
    900
    225-
    900
    300-
    900
    225-
    900
    300-
    900
    150-
    600
    200-
    600
    113-450 150-450
    Double-Rotator Flowmeter-St. steel high temp. type (+150°C ~ +250°C)
    Accuracy: 0.5% and 0.2%                        Table.7
     
    Nominal
    Dia.
    (mm)
    Range of flow m3/h Pulse equivalent liter/pulse
    2-5 mPa.s 5-50 mPa.s 50-400 mPa.s 400-2000 mPa.s 2000-20000 mPa.s
    Light diesel Crude oil, heavy oil Crude oil, heavy oil Hi-viscosity
    Liquid
    Liquid with high water content& super-high viscosity liquid
    0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2
    40 7.5-22.5 10-20 7.5-22.5 10-20 7.5-22.5 10-20 5-15 6-12 4-12 5-10 0.01
    50 12-36 16-32 12-36 16-32 12-36 16-32 7.5-
    22.5
    10-20 6-18 9-18
    80 26.7-80 35-75 26.7-80 35-75 26.7-80 35-75 16-48 20-40 12-36 15-30  
    0.1
    100 34-
    100
    45-90 34-
    100
    45-90 34-
    100
    45-90 20-60 25-50 15-45 20-40
    150 75-
    220
    110-
    220
    75-
    220
    110-
    220
    75-
    220
    110-
    220
    45-135 50-100 30-90 40-80
    200 120-
    360
    180-
    360
    120-
    360
    180-
    360
    120-
    360
    180-
    360
    65-
    200
    80-
    160
    50-
    150
    65-130
     

    Double-Rotator Flowmeter-Carbon steel high temp. type (+150°C ~ +250°C)
         Accuracy: 0.5, 0.2                                  Table.8
    Nominal
    Dia.
    (mm)
    Range of flow m3/h Pulse equivalent liter/pulse
    2-5 mPa.s 5-50 mPa.s 50-400 mPa.s 400-2000 mPa.s 2000-20000 mPa.s
    Light diesel Crude oil, heavy oil Crude oil, heavy oil Hi-viscosity
    Liquid
    Liquid with high water content& super-high viscosity liquid
    0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2
    40 4.5-22.5 5.6-22.5 4.5-22.5 5.6-22.5 4.5-22.5 5.6-22.5 4.2-18 5-15 3-12 4-12 0.01
    50 7.2-36 9-36 7.2-
    36
    9-36 7.2-
    36
    9-36 6-24 7.5-
    22.5
    4.5-
    18
    5.5-17.5
    80 16-80 20-80 16-80 20-80 16-80 20-80 14-56 16-48 10-40 12-36 0.1
    100 20-100 25-100 20-100 25-100 20-100 25-100 18-72 20-60 14-54 16-48
    150 45-220 55-220 45-220 55-220 45-220 55-220 38-150 45-135 25-100 30-90
    200 72-360 90-360 72-360 90-360 72-360 90-360 53-210 65-200 40-160 50-150
    250 108-540 135-540 108-540 135-540 108-540 135-540 72-360 90-360 60-240 80-240
    300 180-900 225-900 180-900 225-900 180-900 225-900 120-600 150-600 113-450 150-450
    Note: The flowmeter is also suitable for interim measurement during installing/uninstalling and ship installing.

    Applications:Double Rotator Flow Meter for Ship Yard with BV CCS

    Double Rotator Flow Meter for Ship Yard with BV CCS
  2. Double Rotator Flow Meter for Ship Yard with BV CCS
  3. Why Yinuo
    (1) For electronic products, we have automatic chip mounter (SMT) production line and high/low temp. testing equipment.
    (2) For mechanical products, we have advantage on casting, machining, and welding which is the key point in eyes of Russian.
    (3) For calibration, we have calibration facilities approved by China government for oil, water and gas.
    (4) For flowmeter, we are Top leaders in China for both of Coriolis Mass Flowmeter & PD flowmeter, which be approved the UL, CE, CCS (China) and BV certificate (France) for marine market.
    (5) For pump, we combined Russian military technology with China low cost to manufacture for large capacity transportation of oil, chemical, water, and wastewater even if contain some participles and we also design and produce twin-screw pump for high pressure, high viscosity liquid with multiphase.
    (6) For SCADA loading & metering/ Skid Mount System, we also have much experience in China and in Afghanistan, Equatorial Guinea and are trying to promote in all over the world.
     

    FAQ.                                                                                                                                               
    1.Customer: What's the delivery date?

    YINUO    : Our stock is based on GB/DIN flange, and the delivery date for it is 10 days; we also accept the other flanges like ANSI/JIS or thread connection, and the delivery date is 15 days.;

    2.Customer: Could you design according to my requirements?

    YINUO    : Yes, we could provide OEM service.

    3. Customer: What's the warranty period?

    YINUO    : Our warranty period is 12 months after
    installation but not longer than 18 months after the shipment.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier