Integrated Type Vortex Flowmeter for Steam with CE Certificate

Product Details
Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Nature Gas, Steam
Size: Dn15 - Dn300
Still deciding? Get samples of US$ 725/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (28)
  • Integrated Type Vortex Flowmeter for Steam with CE Certificate
  • Integrated Type Vortex Flowmeter for Steam with CE Certificate
  • Integrated Type Vortex Flowmeter for Steam with CE Certificate
  • Integrated Type Vortex Flowmeter for Steam with CE Certificate
  • Integrated Type Vortex Flowmeter for Steam with CE Certificate
  • Integrated Type Vortex Flowmeter for Steam with CE Certificate
Find Similar Products

Basic Info.

Model NO.
LXW
Sensor
Tube/Flange
Application
Energy Metering
Type
Vortex Flow Meter
Measuring Media
Liquid and Gas
Measuring Principle
Vortex
Measurement Object
Closed Pipeline
Certification
JIS, GB, CE
Transport Package
Wooden Case
Trademark
YINUO
Origin
Shanghai, China.
HS Code
9026100000
Production Capacity
4000

Product Description

Integrated type Vortex flowmeter for steam with CE 
They choose our Yinuo:
Integrated Type Vortex Flowmeter for Steam with CE Certificate


General

LXW- Series vortex flowmeter is manufactured and designed according to the principle of Kamen vortex flow. Put a drum vertically into a burette and let some fluid flow down along the drum, by two sides of which there formed, in rotation, regular vortexes , which is called the Karman Street. A output frequency of the Karman Street is related to fluid velocity and drum diameter,
Where,
 
f=St·v/d
 
f-Output frequency of the Karman Street    
St-Coefficient (called as Strohar number)   
v-velocity
d-Diameter of drum
 Integrated Type Vortex Flowmeter for Steam with CE Certificate
Q = f/k  
Note:     Q: the quantity flow
f: the frequency of the flow
k: the instrument coefficient

 Integrated Type Vortex Flowmeter for Steam with CE Certificate

As a output frequency of the Karman Street f is direct proportional to a velocity v. It may work out an instantaneous flow rate by using a tested output frequency of the Karman Street. The Strohar number is a key coefficient for vortex street flow meters. Within the lineal section of the curve, where St≈0.17, the output frequency is direct proportional to the flow velocity, so a velocity v is derivable by using a tested frequency f.
 

1.1 Feature                                          

  •  Compact and durable, high reliability, with no movable parts, can be stably used in a long run.
  • Easy to install and maintain
  • No direct contact between transducer and tested material, reliable and have a long life circle.
  • Output is a pulse signal that is proportional to traffic; has high precision and no zero offset.
  • A Large rang of measurement with up to 1:10 rang ratio.
  • Lower pressure loss and operating cost makes more sense on energy saving.
  • Within certain rang of Renault figure, the output signal frequency is free from the influence of physical property and grouping variety, and its instrument factors only involve with figure and size of vortex generators. Thus, no compensation is needed when measuring volume traffic, while no instrument factors needed to be recalibrated when a part changed.
  • It's so widely used that it can measure steam and gas as well as liquid. 

1.2 Technical Data                                  

  • Nominal pressure :   1.6~32MPa
  • Medium temp.  :    -40ºC~300ºC
  • Power Supply :24VDC±10%
  • Ambient Temp. : -25ºC~60ºC
  • Relative humidity : 5%~95%
  • Atmospheric pressure : 86~106Kpa
  • Test medium : liquid, gas and steam
  • Accuracy       Pulse:  +/- 1% (liquid)
        +/- 1% (gas, less than 35m/s)
        +/- 1.5% (gas, more than 35m/s)
  • Current:     +/- 1.2% (liquid)
        +/- 1.2% (gas, less than 35m/s)
        +/- 1.7% (gas, more than 35m/s)
  • Output signal   Analog signals and current  
  • Painting: Option (select the prefer color in the color table which attachment at the end of this manual)
  • Reynolds No. range: 2x104~7x106(DN25~DN100)                      4x104~7x106(DN150~DN300)
     

1.3 Applications Fields

  • Waste water treatment, sewage process
  • Heat exchangers, Cooling systems
  • Oil field metallurgy
  • Ground water remediation
  • And other conductive liquid
  • Chemical industry, petrol-chemical light industry
  • food beverage dispensing
  • Pharmaceutical
  • process control
  • Other field use 
  •  
  •  1.4 ENGINEERING FLOW RANGE                                                        
  • ENGINEERING FLOW RANGE (GENERAL FLUID Table 1 )                         
     
    DN (mm) Normal measure range (m3/h)
    Liquid Gas
    15 0.4~4 5~30
    25 1.5~15 10~100
    40 3.6~36 15~300
    50 6~60 35~500
    80 11~110 60~1050
    100 17~170 100~1850
    150 27~360 170~3600
    200 60~780 400~7000
    250 90~1200 700~11000
    300 160~1720 1000~16000
    Notes:1)  the vortex Flowmeter will be calibrated by water or air based on measuring medium before factory
               2) the gas flow range is based on standard condition 20ºC, 0.1MPa( absolute pressure) or under atmosphere at 20ºC
     
    ENGINEERING FLOW RANGE OF SATURATED STEAM(Table 2)
     
    DN
     
    Pressure
    25mm 32mm 40mm 50mm 65mm 80mm 100mm 125mm 150mm 200mm Temp
    ºC
    Density
    Kg/h
     
    Min.    Max. Min.    Max. Min.    Max. Min.    Max. Min.    Max. Min.    Max. Min.    Max. Min.    Max. Min.    Max. Min.    Max.    
    0.1 20 101 22.5 150 36 229 59 358 93 600 129       917 220 1.43 348 2.25 479 3.22 840 5.73 120.1 1.126
    0.2 21 136 29.5 210 47 333 77 520 124 880 168 1.33 288 2.08 463 3.30 628 4.68 1.10 8.34 133.3 1.638
    0.3 24 151 36 280 56 436 92 680 162 1.15 201 1.74 345 2.78 567 4.30 750 6.13 1.32 11.0 143.2 2.140
    0.4 27 186 42 340 65 536 105 836 171 1.40 231 2.14 396 3.39 640 5.24 862 7.54 1.51 13.6 151.4 2.635
    0.5 30 248 46 410 72 636 118 994 188 1.69 259 2.55 444 3.98 691 6.23 966 8.95 1.70 15.9 158.3 3.127
    0.6 34 256 50 470 80 733 130 1.15 206 1.95 285 2.94 489 4.66 766 7.20 1.07 10.3 1.87 18.6 164.4 3.615
    0.7 37 325 54 530 87 833 142 1.30 225 2.20 310 3.34 531 5.22 832 8.15 1.16 11.7 2.08 20.9 169.8 4.099
    0.8 39 325 58 600 93 931 152 1.45 243 2.47 334 3.73 572 5.91 888 9.10 1.25 13.1 2.19 23.6 174.7 4.581
    0.9 42 394 62 650 100 1.03 163 1.61 253 2.73 357 4.12 612 6.44 936 10.0 1.34 14.5 2.34 25.8 179.2 5.064
    1.0 45 441 66 720 106 1.13 173 1.70 272 3.00 379 4.51 650 7.16 1.00 11.0 1.42 15.8 2.49 28.6 183.3 5.553
    1.1 47 479 70 780 112 1.23 183 1.92 289 3.26 401 4.91 687 7.67 1.07 12.0 1.50 17.3 2.63 30.7 187.2 6.033
    1.2 50 463 73 850 118 1.32 193 2.05 306 3.50 422 5.29 723 8.4 1.12 13.0 1.58 18.5 2.76 33.6 190.8 6.509
    1.3 52 555 77 910 123 1.42 202 2.22 314 3.77 422 5.68 757 8.88 1.17 13.9 1.65 20.0 2.89 35.5 194.2 6.980
    1.4 54 593 79 970 129 1.51 211 2.37 328 4.00 461 6.07 792 9.49 1.22 14.8 1.73 21.3 3.02 37.0 197.5 7.456
    1.5 57 630 82 1.00 135 1.60 219 2.52 341 4.30 481 6.47 825 10.3 1.26 15.8 1.80 22.6 3.15 41.4 200.5 7.934
    1.6 59 669 86 1.1 140 1.71 229 2.68 353 4.55 501 6.86 858 10.7 1.31 16.8 1.87 24.1 3.28 42.9 203.5 8.419
    1.7 61 707 89 1.15 146 1.81 237 2.83 365 4.80 519 7.24 890 11.3 1.36 17.7 1.94 25.9 3.40 45.3 206.2 8.897
    1.8 63 746 93 1.22 151 1.91 246 2.98 385 5.07 538 7.64 922 11.9 1.41 18.7 2.01 26.9 3.53 47.8 208.9 9.388
    1.9 66 784 96 1.28 155 2.01 254 3.14 395 5.33 556 8.03 954 12.6 1.46 19.6 2.08 28.3 3.65 50.0 211.5 9.868
    2.0 68 822 98 1.35 161 2.10 262 3.27 404 5.60 574 8.43 985 13.2 1.50 20.6 2.15 29.6 3.76 53.5 213.9 10.35
    3.0 87 1.21 128 1.98 207 3.10 338 4.84 532 8.21 743 12.4 1.27 19.3 1.95 30.3 2.78 43.5 4.86 77.4 234.6 15.21
    4.0 106 1.61 158 2.60 251 4.11 409 6.43 647 11.0 898 16.5 1.53 25.7 2.40 40.2 2.35 57.8 5.87 102.8 250.7 20.21
    4.3 111.0 1.730 161.0 2.80 264.0 4.43 429.0 6.91 666.0    11.6 942.0 17.7 1.61 27.7 2.47 43.0 3.52 62.2 6.17 110.6 254.9 21.74
     
     
     
     HANDLING PRECAUTIO                             
    The LXW Series Vortex Flowmeter are thoroughly tested at the factory before shipment. When these instruments are delivered, perform a visual check to ascertain that no damage occurred during shipment. This section describes important cautions in handling these instruments. Read carefully before using them. If you have any problems or questions, contact your nearest
    GPE Inc. service center or sales representative.
    2.1 Precautions Regarding Transportation and Storage Location
    To protect against accidental damage to vortex flowmeter while transporting it to a new location, pack it in the original
    packing as when shipped from YINUO factory.
    WARNING!
    The Vortex Flowmeter is a heavy instrument. Please be careful to prevent persons from injuring when it is handled. Deterioration in insulation or corrosion can occur for unexpected reasons if vortex flowmeter is left uninstalled for a prolonged period after delivery. If vortex flowmeter is likely to be stored over a prolonged period, observe the following precautions.
    Store the vortex flowmeter with forwarded statement.
    Choose a storage location that satisfies the following requirements:
    • Not exposed to rain or splashwater.
    • Less susceptible to mechanical vibration or shock.
    • Kept within the temperature and humidity ranges shown in the following table, preferably at normal temperature and humidity (approximately 25°C, 65%)
    Temperature -25°C to +60°C
    Humidity 5 to 95% (no condensation)
     
     
    2.2  Precautions Regarding Installation Locations
  • Ambient Temperature
    Avoid an area which has wide temperature variations.When the installation area is subjected to heat radiation from process plant, ensure adequate heat prevention or ventilation.
  • Atmospheric Conditions Avoid installing the vortex flowmeter in a corrosive atmosphere. When the vortex flowmeter must be installed in a corrosive atmosphere, adequate ventilation must be provided
  • Mechanical Shock or Vibration
    The vortex flowmeter is of sturdy construction, but elect an area subject to minimize mechanical vibration or impact shock. If the flowmeter is subject to vibrations, it is recommended that pipeline supports to be provided as shown in Figure 4.