Shanghai, China
Business Type:
Manufacturer/Factory & Trading Company
Main Products:
Number of Employees:
359
Year of Establishment:
1999-06-24
Management System Certification:
ISO9001:2008, ISO14001:2004, OHSAS18001:2007
OEM/ODM Availability:
Yes
OEM/ODM Service
Sample Available
MEI Awards
Russian Speaker

Jacket Type Flowmeter, Bitumen Flowmeter, Thermal Jacket manufacturer / supplier in China, offering Jacket Type Pd Meter, Coriolis Mass Flowmeter (LZYN) for Liquid & High Pressure Gas, High Accuracy Micro-Bend Coriolis Mass Flow Meter (LZYN) and so on.

Gold Member Since 2017
Audited Supplier

Jacket Type Pd Meter

Get Latest Price
Min. Order: 1 Piece
Port: Shanghai, China
Production Capacity: 5000units Per Year
Payment Terms: L/C, T/T, D/P, Paypal
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas, High Viscosity Liquid
Size: Dn8mm -Dn400mm
Sensor: Tube/Flange
Application: Energy Metering
Type: Volume Type Flow Meter

You Might Also Like

Loading...

Basic Info

Model NO.: LSZ
Measuring Media: Liquid
Measuring Principle: Volumetric
Measurement Object: Closed Pipeline
Certification: JIS, DIN, GB, CE, ISO
Trademark: YINUO
Transport Package: Wooden Case
Specification: Size from 3/8inch to 16 inch
Origin: Shanghai, China.
HS Code: 9026100000

Product Description


  1.  
LSZ- Double rotator flowmeter series Thermal Jacket 
 
General
LSZ-Jacket flowmeter find extensive use in flow measuring appliations where process materials tends to become highly visous, solidify, or extract as line temperature drops, or where process fluids must be controlled at a specific temperature. Measurement is made while steam or hot oil is allowed to circulate through the jacked enclosure.
 
  Features
  • Superior accuracy to 0.1% of reading over 30:1 turn-down
  • Self-lubricating Very low noise and vibration
  • Rugged double case construction prevents loss of calibration due to changes in pressure or temperature
  • No oscillating, reciprocating or sliding parts or cranks to wear or disturb the balanced rotary action  
  • Field proven in precise tempering of the process fluid that tends to solidify, requiring heat retention.
  • Flowmeter body is of pocketless design-an ideal construction for a jacketed flowmeter.
  • A complete line of meter sizes, registers pulse generators, receiving instruments, etc. are available to meet widely varies  
     
    Construction and Liquid to be metered( Fullly Jacketed)
     
 Sectional View
 
Description Liquids to be metered
 Jacket Type Pd Meter
 
Pocketless construction( transmission system: Magnetic coupling)
Max. operating pressure( pressure of fluid to be metered):1.18MPa
Bitumen, DMT, phthalic
Anhydride,
Naphthalene, etc.
 
 
 
 
Construction and Liquid to be metered( Standard Jacketed)

 General Specification
  • Meter body
              Item            Description
Nominal size mm08~400
ConstructionDouble-case construction
Applicable fluidWater petroleum liquid foods chemical liquids
Flow rangeSee flow range table
Operating temp.range
+
+80~+150°C
+150°C~+250°C
Accuracy0.2%0.5%
Repeatability0.067%0.167%
MaterialsBodyCast steel or 304 stainless steel or 316 stainless steel
RotorsCast steel or 304 stainless steel or 316 stainless steel
BearingsCast steel or 304 stainless steel or 316 stainless steel
 
 
Register Specifications Model M1
ItemDescription
Meter sizeRound Mechanical Register
Units IndicatedStere
Pointer RotationClockwise
Local display(LCD)Cumulative totalizing counter0.1m3(std)  0.01m3  0.001m3
Resettable counter   No
Instantaneous flowrate0.01m3/h(std)
Power supplyWithout output signalInstalled lithium battery
With output signalExternal power source 24 VDC
Ambient temperature-40°C ~ +70°C
Explosionproof configurationNon-explosionproof type
Exd II CT2~T6
Degree of Protection for enclosureIP65
Note, output signal must matched with LPJ-I/F Photoelectric Pulse, then current signal or pulse signal could be chose
 
 
Model VR
ItemDescription
Meter sizeSquare Mechanical Register
Units IndicatedStere
Local display(LCD)Cumulative totalizing counter0.1m3(std)  0.01m3  0.001m3
Resettable counter0.1m3(std)  0.01m3  0.001m3
Instantaneous flowrate No
Power supplyWithout output signalInstalled lithium battery
With output signalExternal power source 24 VDC
Ambient temperature-40°C ~ +70°C
Explosionproof configurationNon-explosionproof type
Exd II CT2~T6
Degree of Protection for enclosureIP65
  1. Note, output signal must matched with LPJ-I/F Photoelectric Pulse, then current signal or pulse signal could be chose


    Main Technical Parameters                                 Table:1
    Nominal Dia. (mm)8~400
    Accuracy ±0.1%, ±0.2% and ±0.5%
    Pressure loss0~1000mPa.s<80Kpa  1000~20000mPa.2<150KPa
    Nominal pressure1.6, 2.5, 4.0, 6.4 MPa
    Temperature range-20°C ~ +80°C  +80°C ~ +150°C  +150°C ~ +250°C
    Media viscosity0~20000mPa.s
    Ambient temperature-40°C ~ +70°C
    Connected flangeCan be custom-made
    Photoelectric pulse(current)converterExd II CT6(Excluding acetylene)
    Electronic meterhead Exd II CT2-T6
    Range of Flow       
    For Accuracy: 0.5% and 0.2%                                                            Table.2
     
    Nominal
    Dia.
    (mm)
    Flow range m3/hPulse equivalent liter/pulse
    0.32-0.8mPa.s0.8-2mPa.s2-5mPa.s5-400mPa.s400-2000mPa.s2000-20000mPa.s
    Gasoline/ liquefied gasKeroseneLight dieselCrude oil, heavy oilHi-viscosity
    Liquid
    Liquid with high water content & super-high viscosity liquid
    0.5%0.2%0.5%0.2%0.5%0.2%0.5%0.2%0.5%0.2%0.5%0.2%
    150.6-3 0.4-4 0.4-4 0.4-4 0.3-2.4 0.3-2.4 0.001
    253-8 1.5-10 1-10 1-10 1-8 1-6  
    0.01
     
    408-208-202.7-225.5-222.5-254.4-222.5-254.4-222.1-184.2-181.5-123-12
    509-3615-364.5-369-364-407.2-364-407.2-362.8-246-242.2-184.5-18
    8020-8032-8010-8020-809-9016-809-9016-806.5-5614-565-4010-40 
     
     
    0.1
    10025-10040-10013-10025-10012-12020-10012-12020-1008.5-7218-726.5-5414-54
    15055-22588-22031-25057-22525-25044-22025-25044-22018-15038-15012-10025-100
    20090-360150-36050-40090-36040-40072-36040-40072-36028-24053-21020-16040-160
    250135-540180-54068-540135-54060-600108-54060-600108-54042-36090-36030-24060-240
    300220-900300-900112-900225-900100-1000180-900100-1000180-90070-600150-60054-450113-450
    400400-1600550-1600200-1600400-1600180-1800320-1600180-800320-1600130-1100275-110090-750180-750
    Double-Rotator Flowmeter
    Accuracy: 0.1%                                      Table.3
     
    Nominal
    Dia.
    (mm)
    Flow range m3/hPulse equivalent liter/pulse
    0.32-2 mPa.s
     
    2-5 mPa.s5-50mPa.s   500-400          mPa.s400-2000 mPa.s2000-20000 mPa.s
    Gasoline/ liquefied gasKeroseneLight dieselCrude oil,heavy oilHi-viscosity
    Liquid
    Liquid with high water content & super-high viscosity liquid
    4011-229-227.5-227.5-227.5-224-123.3-100.001
    5018-3614.4-3612-3612-3612-367.5-226-180.01
    8040-8032-8026.7-8026.7-8026.7-10016-4813-40
    10050-10040-10034-10034-10034-10024-7218-54
    150115-22090-22073-22073-22073-22040-12030-900.1
    200180-360144-360120-360120-360120-36060-18050-150
    250270-540216-540180-540180-540180-540100-30060-180
    300450-900360-900300-900300-900300-900200-600150-450
    400800-1600640-1600530-1600530-1600530-1600400-1200300-900
    Double-Rotator Flowmeter-(Electron Meter head)
    Accuracy: 0.5%, 0.2%                                                   Table. 4
     
    Nominal
    Dia.
    (mm)
    Flow range m3/hPulse equivalent liter/pulse
    0.32-0.8mPa.s0.8-2mPa.s2-5mPa.s5-4mPa.s400-2000mPa.s2000-20000mPa.s
    Gasoline/ liquefied gasKeroseneLight dieselCrude oil, heavy oilHi-viscosity
    Liquid
    Liquid with high water content & super-high viscosity liquid
    0.50.20.50.20.50.20.50.20.50.20.50.20.01
    80.06-0.30.10-0.30.05-0.30.07-0.30.03-0.30.06-0.30.03-0.30.06-0.30.03-0.270.06-0.270.03-0.240.06-0.24
    15A0.2-0.80.27-0.80.1-10.2-10.1-1.50.1-10.1-1.50.1-10.1-0.80.16-0.80.08-0.70.15-0.7
    15B0.25-10.33-10.25-1.50.25-10.25-30.3-30.3-30.4-30.1-1.50.2-1.50.1-1.20.2-1.2
    251.5-62-61.2-61.5-60.6-101.2-100.6-101.2-100.6-61.2-60.6-51.2-50.1
    Double-Rotator Flowmeter-St. steel (-20°C ~ +80°C)
    Accuracy: 0.5% and 0.2%                              Table.5
    Nominal
    Dia.
    (mm)
    Range of flow m3/hPulse equivalent liter/pulse
    0.32-0.8 mPa.s0.8-2 mPa.s2-5 mPa.s5-400 mPa.s400-2000 mPa.s2000-20000 mPa.s
    Gasoline/ liquefied gasKeroseneLight diesel, dieselCrude oil, heavy oilHi-viscosity
    Liquid
    Liquid with high water content & super-high viscosity liquid
    0.50.20.50.20.50.20.50.20.50.20.50.2
    150.75-3 0.75-3 0.6-3 0.6-3 0.6-3 0.5-2.5 0.001
    252-8 2-8 1.6-8 1.6-8 1.2-6 1-5 
    406-248-246-248-244.8-
    24
    6-244.8-
    24
    6-243.6-
    18
    4-162.4-
    12
    2.5-100.01
    509-3612-369-3612-367.2-
    36
    9-367.2-
    36
    9-364.8-
    24
    5.5-
    22
    3.6-
    18
    4-16
    8020-8027-8020-8027-8016-8020-8016-8020-8012-5612-488-409-360.1
    10025-
    100
    34-
    100
    25-
    100
    34-
    100
    20-
    100
    25-
    100
    20-
    100
    25-
    100
    15-7515-6011-5411-45
    15055-
    220
    75-
    220
    55-
    220
    75-
    220
    45-
    220
    55-
    220
    45-
    220
    55-
    220
    30-
    150
    35-
    135
    20-
    100
    23-90
    20090-
    360
    120-
    360
    90-
    360
    120-
    360
    72-
    360
    90-
    360
    72-
    360
    90-
    360
    43-
    210
    50-
    200
    32-
    160
    38-150
    250135-
    540
    180-
    540
    135-
    540
    180-
    540
    108-
    540
    135-
    540
    108-
    540
    135-
    540
    72-
    360
    90-
    360
    48-
    240
    60-240
    300225-
    900
    300-
    900
    225-
    900
    300-
    900
    180-
    900
    225-
    900
    180-
    900
    225-
    900
    120-
    600
    150-
    600
    90-
    450
    113-450
    Double-Rotator Flowmeter-St. steel high temp. type (+80°C ~ +150°C)
    Accuracy: 0.5, 0.2                                 Table.6
    Nominal
    Dia.
    (mm)
    Range of flow m3/hPulse equivalent liter/pulse
    2-5 mPa.s5-50 mPa.s50-400 mPa.s400-2000 mPa.s2000-20000 mPa.s
    Light dieselCrude oil, heavy oilCrude oil, heavy oilHi-viscosity
    Liquid
    Liquid with high water content& super-high viscosity liquid
    0.50.20.50.20.50.20.50.20.50.2
    405.6-
    22.5
    7-205.6-
    22.5
    7-205.6-
    22.5
    7-204-154-123-123.5-100.01
    509-3610-329-3610-329-3610-324.5-227-204.5-186-18
    8020-8025-7520-8025-7520-8025-7512-4813-409-3610-30 
     
    0.1
    10025-
    100
    30-9025-
    100
    30-9025-
    100
    30-9015-6017-5011-4514-40
    15045-
    220
    75-
    220
    45-
    220
    75-
    220
    45-
    220
    75-
    220
    35-
    135
    34-
    100
    23-9027-80
    20090-
    360
    120-
    360
    90-
    360
    120-
    360
    90-
    360
    120-
    360
    50-
    200
    54-
    160
    38-15043-130
    250135-
    540
    180-
    540
    135-
    540
    180-5
    40
    135-
    540
    180-
    540
    90-
    360
    120-
    360
    60-24080-240
    300225-
    900
    300-
    900
    225-
    900
    300-
    900
    225-
    900
    300-
    900
    150-
    600
    200-
    600
    113-450150-450
    Double-Rotator Flowmeter-St. steel high temp. type (+150°C ~ +250°C)
    Accuracy: 0.5% and 0.2%                        Table.7
     
    Nominal
    Dia.
    (mm)
    Range of flow m3/hPulse equivalent liter/pulse
    2-5 mPa.s5-50 mPa.s50-400 mPa.s400-2000 mPa.s2000-20000 mPa.s
    Light dieselCrude oil, heavy oilCrude oil, heavy oilHi-viscosity
    Liquid
    Liquid with high water content& super-high viscosity liquid
    0.50.20.50.20.50.20.50.20.50.2
    407.5-22.510-207.5-22.510-207.5-22.510-205-156-124-125-100.01
    5012-3616-3212-3616-3212-3616-327.5-
    22.5
    10-206-189-18
    8026.7-8035-7526.7-8035-7526.7-8035-7516-4820-4012-3615-30 
    0.1
    10034-
    100
    45-9034-
    100
    45-9034-
    100
    45-9020-6025-5015-4520-40
    15075-
    220
    110-
    220
    75-
    220
    110-
    220
    75-
    220
    110-
    220
    45-13550-10030-9040-80
    200120-
    360
    180-
    360
    120-
    360
    180-
    360
    120-
    360
    180-
    360
    65-
    200
    80-
    160
    50-
    150
    65-130
     

    Double-Rotator Flowmeter-Carbon steel high temp. type (+150°C ~ +250°C)
         Accuracy: 0.5, 0.2                                  Table.8
    Nominal
    Dia.
    (mm)
    Range of flow m3/hPulse equivalent liter/pulse
    2-5 mPa.s5-50 mPa.s50-400 mPa.s400-2000 mPa.s2000-20000 mPa.s
    Light dieselCrude oil, heavy oilCrude oil, heavy oilHi-viscosity
    Liquid
    Liquid with high water content& super-high viscosity liquid
    0.50.20.50.20.50.20.50.20.50.2
    404.5-22.55.6-22.54.5-22.55.6-22.54.5-22.55.6-22.54.2-185-153-124-120.01
    507.2-369-367.2-
    36
    9-367.2-
    36
    9-366-247.5-
    22.5
    4.5-
    18
    5.5-17.5
    8016-8020-8016-8020-8016-8020-8014-5616-4810-4012-360.1
    10020-10025-10020-10025-10020-10025-10018-7220-6014-5416-48
    15045-22055-22045-22055-22045-22055-22038-15045-13525-10030-90
    20072-36090-36072-36090-36072-36090-36053-21065-20040-16050-150
    250108-540135-540108-540135-540108-540135-54072-36090-36060-24080-240
    300180-900225-900180-900225-900180-900225-900120-600150-600113-450150-450
    Note: The flowmeter is also suitable for interim measurement during installing/uninstalling and ship installing.

    Applications:

    Jacket Type Pd Meter

    Jacket Type Pd Meter

    Jacket Type Pd Meter














  2.  
  3.  
  4.  
  5.  
  6.  

Send your message to this supplier

*From:
*To:
avatar Mr. Alex
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now